Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
JCO Oncol Pract ; : OP2300816, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38662969

RESUMEN

This review critically analyzes the incidence of trastuzumab-induced left ventricular systolic dysfunction and congestive heart failure (CHF), distinguishing between cases with and without prior anthracycline exposure. It highlights the fact that the elevated risk of trastuzumab-induced cardiotoxicity is closely associated with prior anthracycline exposure. In the absence of prior anthracycline exposure, the incidence rates of trastuzumab-induced cardiotoxicity, particularly CHF (ranging from 0% to 0.5%), are largely comparable with those reported in the general population, especially when reversibility is taken into account. Current cardiac surveillance recommendations during trastuzumab treatment have not yet adapted to the increasing adoption of nonanthracycline treatment strategies and the associated low risk of cardiotoxicity. We propose a refined monitoring protocol to reduce the frequency of cardiac evaluations for low-risk to moderate-risk patients, especially those receiving nonanthracycline treatments. By focusing on patients at high risk or those with prior anthracycline exposure, this strategy seeks to optimize the cost-effectiveness of cardiac care in oncology.

2.
Catheter Cardiovasc Interv ; 103(6): 833-842, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38639137

RESUMEN

BACKGROUND: Stent underexpansion, typically related to lesion calcification, is the strongest predictor of adverse events after percutaneous coronary intervention (PCI). Although uncommon, underexpansion may also occur in non-severely calcified lesions. AIM: We sought to identify the prevalence and anatomical characteristics of underexpansion in non-severely calcified lesions. METHODS: We included 993 patients who underwent optical coherence tomography-guided PCI of 1051 de novo lesions with maximum calcium arc <180°. Negative remodeling (NR) was the smallest lesion site external elastic lamina diameter that was also smaller than the distal reference. Stent expansion was evaluated using a linear regression model accounting for vessel tapering; underexpansion required both stent expansion <70% and stent area <4.5mm2. RESULTS: Underexpansion was observed in 3.6% of non-heavily calcified lesions (38/1051). Pre-stent maximum calcium arc and thickness were greater in lesions with versus without underexpansion (median 119° vs. 85°, p = 0.002; median 0.95 mm vs. 0.78 mm, p = 0.008). NR was also more common in lesions with underexpansion (44.7% vs. 24.5%, p = 0.007). In the multivariable logistic regression model, larger and thicker eccentric calcium, mid left anterior descending artery (LAD) location, and NR were associated with underexpansion in non-severely calcified lesions. The rate of underexpansion was especially high (30.7%) in lesions exhibiting all three morphologies. Two-year TLF tended to be higher in underexpanded versus non-underexpanded stents (9.7% vs. 3.7%, unadjusted hazard ratio [95% confidence interval] = 3.02 [0.92, 9.58], p = 0.06). CONCLUSION: Although underexpansion in the absence of severe calcium (<180°) is uncommon, mid-LAD lesions with NR and large and thick eccentric calcium were associated with underexpansion.


Asunto(s)
Enfermedad de la Arteria Coronaria , Vasos Coronarios , Intervención Coronaria Percutánea , Stents , Tomografía de Coherencia Óptica , Calcificación Vascular , Humanos , Masculino , Femenino , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/efectos adversos , Anciano , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Prevalencia , Factores de Riesgo , Vasos Coronarios/diagnóstico por imagen , Resultado del Tratamiento , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Diseño de Prótesis , Valor Predictivo de las Pruebas , Factores de Tiempo , Angiografía Coronaria , Remodelación Vascular
3.
Artículo en Inglés | MEDLINE | ID: mdl-38676848

RESUMEN

Contrast enhanced pulmonary vein magnetic resonance angiography (PV CE-MRA) has value in atrial ablation pre-procedural planning. We aimed to provide high fidelity, ECG gated PV CE-MRA accelerated by variable density Cartesian sampling (VD-CASPR) with image navigator (iNAV) respiratory motion correction acquired in under 4 min. We describe its use in part during the global iodinated contrast shortage. VD-CASPR/iNAV framework was applied to ECG-gated inversion and saturation recovery gradient recalled echo PV CE-MRA in 65 patients (66 exams) using .15 mmol/kg Gadobutrol. Image quality was assessed by three physicians, and anatomical segmentation quality by two technologists. Left atrial SNR and left atrial/myocardial CNR were measured. 12 patients had CTA within 6 months of MRA. Two readers assessed PV ostial measurements versus CTA for intermodality/interobserver agreement. Inter-rater/intermodality reliability, reproducibility of ostial measurements, SNR/CNR, image, and anatomical segmentation quality was compared. The mean acquisition time was 3.58 ± 0.60 min. Of 35 PV pre-ablation datasets (34 patients), mean anatomical segmentation quality score was 3.66 ± 0.54 and 3.63 ± 0.55 as rated by technologists 1 and 2, respectively (p = 0.7113). Good/excellent anatomical segmentation quality (grade 3/4) was seen in 97% of exams. Each rated one exam as moderate quality (grade 2). 95% received a majority image quality score of good/excellent by three physicians. Ostial PV measurements correlated moderate to excellently with CTA (ICCs range 0.52-0.86). No difference in SNR was observed between IR and SR. High quality PV CE-MRA is possible in under 4 min using iNAV bolus timing/motion correction and VD-CASPR.

4.
Am J Cardiol ; 218: 102-112, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38432332

RESUMEN

There are various devices under clinical investigation for transcatheter mitral valve intervention and transcatheter tricuspid valve intervention (TTVI); however, the exclusion rates remain high. We aimed to investigate the exclusion rates for transcatheter mitral valve repair (TMVr), transcatheter mitral valve replacement (TMVR), transcatheter tricuspid valve repair (TTVr), and transcatheter tricuspid valve replacement (TTVR). There were 129 patients who were referred to St. Francis Hospital & Heart Center valve clinic and completed screening between January 2021 and July 2022. The causes for exclusion were classified into 4 categories: patient withdrawal, anatomic unsuitability, clinical criteria, and medical futility. In 129 patients, the exclusion rates for TMVr, TMVR, TTVr, and TTVR were 81%, 85%, 91%, and 87%, respectively. Patient withdrawal and medical futility were leading etiologies for exclusion, followed by anatomic unsuitability. TMVr had the highest rate of patient withdrawal (64%) and the lowest anatomic unsuitability (5%) because of short posterior leaflet length. Replacement interventions have a higher anatomic unsuitability (33%) than repair interventions (17%) (p = 0.04). Most exclusions of anatomic unsuitability were because of mitral stenosis or small annulus size for TMVR and large annulus size for TTVR. A total of 50% of exclusions from TTVr were because of the presence of pacemaker/defibrillator leads. In patients excluded from their respective trials, patients being referred for TMVr had the highest recurrent hospitalization and repair group had a higher mortality (p <0.01 and p = 0.01, respectively). In conclusion, the exclusion rates for transcatheter mitral valve intervention and TTVI trials remain high because of various reasons, limiting patient enrollment and treatment. This supports the need for further device improvement or exploring alternative means of therapy.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Tricúspide/cirugía , Cateterismo Cardíaco , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/cirugía , Hospitales
5.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38552656

RESUMEN

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
7.
Ann Thorac Surg ; 2024 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-38316377

RESUMEN

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.

8.
Circ Cardiovasc Interv ; 16(11): e012966, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37988437

RESUMEN

Transcatheter aortic valve replacement (TAVR) is increasingly being performed in younger and lower surgical risk patients. Reintervention for failed transcatheter heart valves will likely increase in the future as younger patients are expected to outlive the initial bioprosthesis. While redo-TAVR has emerged as an attractive and less invasive alternative to surgical explantation (TAVR-explant) to treat transcatheter heart valve failure, it may not be feasible in all patients due to the risk of coronary obstruction and impaired coronary access. Conversely, TAVR-explant can be offered to most patients who are surgical candidates, but the reported outcomes have shown high mortality and morbidity. This review provides the latest evidence, current challenges, and future directions on redo-TAVR and TAVR-explant for transcatheter heart valve failure, to guide aortic valve reintervention and facilitate patients' lifetime management of aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
9.
Ann Thorac Surg ; 116(5): 908-932, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37804270

RESUMEN

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Comorbilidad , Cateterismo Cardíaco/efectos adversos , Índice de Severidad de la Enfermedad
10.
J Am Coll Cardiol ; 82(17): 1711-1735, 2023 10 24.
Artículo en Inglés | MEDLINE | ID: mdl-37804294

RESUMEN

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Índice de Severidad de la Enfermedad
11.
Eur Heart J ; 44(43): 4508-4532, 2023 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-37793121

RESUMEN

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Índice de Severidad de la Enfermedad
12.
Am J Cardiol ; 205: 311-320, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37633066

RESUMEN

In severe aortic stenosis (AS), there are conflicting data on the prognostic implications of left ventricular (LV) hypertrophy (LVH). We aimed to characterize the LV geometry, myocardial matrix structural changes, and prognostic stratification using cardiac magnetic resonance imaging (CMR) and echocardiography in subjects with severe AS with and without LVH. Consecutive patients who had severe isolated AS and sufficient quality echocardiography and CMR within 6 months of each other were evaluated for LVH, cardiac structure, morphology, and late gadolinium-enhancement imaging. Kaplan-Meier curves, linear models, and proportional hazards models were used for prognostic stratification. There were 93 patients enrolled (mean age 74 ± 11 years, 48% female), of whom 38 (41%) had a normal LV mass index (LVMI), 41 (44%) had LVH defined at CMR by LVMI >2 SD higher than normal, and 14 (15% of the total) with >4 SD higher than the reference LVMI (severely elevated). The Society of Thoracic Surgeons scores were similar among the LVMI groups. Compared with those with normal LVMI, patients with LVH had higher LV end-diastolic and end-systolic volumes, increased late gadolinium-enhancement burden, and lower LV ejection fraction. Most notably, CMR feature-tracking global radial strain, 2-dimensional speckle-tracking echocardiography global longitudinal strain, and left atrial reservoir function were significantly worse. On the survival analyses, LVMI was not associated with a composite of all-cause mortality and/or heart failure hospitalization. In conclusion, compared with normal LVMI, elevated LVMI was not associated with a higher risk of adverse outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Gadolinio , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Miocardio , Ecocardiografía , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Imagen por Resonancia Magnética , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/diagnóstico por imagen
14.
Struct Heart ; 7(3): 100164, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37273856

RESUMEN

Background: Cardiac computed tomography angiography was used to identify anatomical characteristics of the aortic root in patients with severe aortic regurgitation (AR) as compared to those with aortic stenosis (AS) to judge feasibility of transcatheter aortic valve replacement (TAVR) with the JenaValve Trilogy system. Methods: Cardiac computed tomography angiography was performed prior to planned TAVR for 107 patients with severe AR and 92 patients with severe AS. Measurements related to aortic root and coronary artery anatomy were obtained and compared between groups. Perimeter >90 mm and aortic annulus angle â€‹>70 degrees were defined as the theoretical exclusion criteria for TAVR. A combination of sinus of Valsalva diameter <30 mm and coronary height <12 mm was defined as high risk for coronary occlusion. Results: The mean age of patients in the AR group was 74.9 ± 11.2 years, 46% were women, and the mean Society of Thoracic Surgeons risk score for mortality was 3.6 ± 2.1. Comparatively, the mean age of patients in the AS group was 82.3 ± 5.53 years, 65% were women, and the mean Society of Thoracic Surgeonsrisk score was 5.5 ± 3.3. Annulus area, perimeter, diameter, and angle were larger in patients with severe AR. Sinus of Valsalva diameters and heights were larger in patients with severe AR. More AR patients were excluded based on perimeter (14 vs. 2%) and annulus angle (6 vs. 1%). More AS patients exhibited high-risk anatomy for left main coronary occlusion (21 vs. 7%) and right coronary occlusion (14 vs. 3%). The maximum dimension of the ascending aorta was larger in patients with severe AR (39 vs. 35 mm). The percentage of referred AR patients with significant aortopathy requiring surgical intervention was very low (only 1 AR patient with ascending aorta diameter >5.5 cm). Conclusions: A significantly larger proportion of patients with severe AR are excluded from TAVR as compared to AS due to large aortic annulus size and steep annulus angulation. By far the most prevalent excluding factor is aortic annulus size, with fewer patients excluded due to angulation. AR patients have lower-risk anatomy for coronary occlusion. Larger transcatheter valve sizes and further delivery system modifications are required to treat a larger proportion of AR patients.

15.
JACC Cardiovasc Interv ; 16(9): 1024-1035, 2023 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-37164599

RESUMEN

BACKGROUND: Whether an eruptive or noneruptive target lesion calcified nodule (CN) portends worse acute and long-term clinical outcomes after stenting has not been established. OBJECTIVES: The authors sought to compare acute and long-term clinical outcomes in eruptive CN vs noneruptive CN morphology. METHODS: Using optical coherence tomography, an eruptive CN was defined as an accumulation of small calcium fragments protruding and disrupting the overlying fibrous cap, typically with small amount of thrombus. A noneruptive CN was defined as an accumulation of small calcium fragments with a smooth intact fibrous cap without an overlying thrombus. The primary endpoint was target lesion failure (TLF) including cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization in patients with ≥6-month follow-up. RESULTS: Among 3,231 patients with evaluable pre- and postintervention OCT, 236 patients had lesions with CNs (7.3%). After eliminating 4 secondary lesions and 6 patients without ≥6-month follow-up, 126 (54.8%) lesions with eruptive CNs and 104 (45.2%) lesions with noneruptive CNs formed the current report. Compared with noneruptive CNs, eruptive CNs were independently associated with greater stent expansion (89.2% ± 18.7% vs. 81.5% ± 18.9%; P = 0.003) after adjusting for morphologic and procedural factors. At 2 years, eruptive CNs trended toward more TLF compared with noneruptive CNs (Kaplan-Meier estimates, 19.8% vs 12.5%; P = 0.11) and significantly more target lesion revascularization (18.3% vs 9.6%; P = 0.04). In the adjusted model, eruptive CNs were independently associated with 2-year TLF (HR: 2.07; 95% CI: 1.01-4.50; P = 0.048). CONCLUSIONS: Compared with noneruptive CN morphology, lesions with an eruptive CN appearance on optical coherence tomography had a worse poststent long-term clinical outcome despite better acute stent expansion.


Asunto(s)
Enfermedad de la Arteria Coronaria , Exantema , Intervención Coronaria Percutánea , Trombosis , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Calcio , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Stents , Fibrosis
17.
JACC Cardiovasc Interv ; 15(18): 1823-1833, 2022 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-36137685

RESUMEN

BACKGROUND: Physiologic right ventricle-pulmonary artery (RV-PA) coupling may be impaired in patients with aortic stenosis (AS). OBJECTIVES: This study aimed to assess the incidence and prognostic significance of impaired RV-PA coupling in low-risk patients with symptomatic severe AS undergoing transcatheter aortic valve replacement or surgical aortic valve replacement. METHODS: RV-PA coupling was measured by transthoracic echocardiography as the ratio of tricuspid annular plane systolic excursion (TAPSE) to pulmonary artery systolic pressure (PASP) in patients in the PARTNER (Placement of Aortic Transcatheter Valve) 3 trial. The primary endpoint was the composite of all-cause mortality, stroke, and rehospitalization at the 2-year follow-up. RESULTS: Among 570 low-risk patients included in the analysis, RV-PA uncoupling was defined by a TAPSE/PASP ratio ≤ 0.55 mm/mm Hg. At baseline, 222 of 570 (38.9%) patients had RV-PA uncoupling. At 2 years, patients with baseline RV-PA uncoupling had an increased incidence of the primary endpoint (19.1% vs 9.9%, P = 0.002), all-cause mortality (5.9% vs 0.6%, P < 0.001), cardiovascular mortality (4.1% vs 0.6%, P = 0.003), and rehospitalization (13.5% vs 7.3%, P = 0.018). On multivariable analysis, baseline RV-PA uncoupling remained an independent predictor of the primary endpoint at 2 years (HR: 1.92; 95% CI: 1.04-3.57; P = 0.038). CONCLUSIONS: In patients with symptomatic severe AS at low surgical risk undergoing transcatheter aortic valve replacement or surgical aortic valve replacement, baseline RV-PA uncoupling defined by TAPSE/PASP ≤ 0.55 mm Hg was associated with adverse clinical outcomes at 2 years, including all-cause mortality, cardiovascular mortality, and rehospitalization.


Asunto(s)
Estenosis de la Válvula Aórtica , Disfunción Ventricular Derecha , Humanos , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ventrículos Cardíacos , Arteria Pulmonar/diagnóstico por imagen , Resultado del Tratamiento , Función Ventricular Derecha
18.
Artículo en Inglés | MEDLINE | ID: mdl-36153166

RESUMEN

OBJECTIVE: Implantation of a transcatheter valve-in-mitral annular calcification (ViMAC) has emerged as an alternative to traditional surgical mitral valve (MV) replacement. Previous studies evaluating ViMAC aggregated transseptal, transapical, and transatrial forms of the procedure, leaving uncertainty about each technique's advantages and disadvantages. Thus, we sought to evaluate clinical outcomes specifically for transatrial ViMAC from the largest multicenter registry to-date. METHODS: Patients with symptomatic MV dysfunction and severe MAC who underwent ViMAC were enrolled from 12 centers across the United States and Europe. Clinical characteristics, procedural details, and clinical outcomes were abstracted from the electronic record. The primary end point was all-cause mortality. RESULTS: We analyzed 126 patients who underwent ViMAC (median age 76 years [interquartile range {IQR}, 70-82 years], 28.6% female, median Society of Thoracic Surgeons score 6.8% [IQR, 4.0-11.4], and median follow-up 89 days [IQR, 16-383.5]). Sixty-one (48.4%) had isolated mitral stenosis, 25 (19.8%) had isolated mitral regurgitation (MR), and 40 (31.7%) had mixed MV disease. Technical success was achieved in 119 (94.4%) patients. Thirty (23.8%) patients underwent concurrent septal myectomy, and 8 (6.3%) patients experienced left ventricular outflow tract obstruction (7/8 did not undergo myectomy). Five (4.2%) patients of 118 with postprocedure echocardiograms had greater than mild paravalvular leak. Thirty-day and 1-year all-cause mortality occurred in 16 and 33 patients, respectively. In multivariable models, moderate or greater MR at baseline was associated with increased risk of 1-year mortality (hazard ratio, 2.31; 95% confidence interval, 1.07-4.99, P = .03). CONCLUSIONS: Transatrial ViMAC is safe and feasible in this selected, male-predominant cohort. Patients with significant MR may derive less benefit from ViMAC than patients with mitral stenosis only.

19.
JACC Cardiovasc Imaging ; 15(7): 1212-1226, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35798397

RESUMEN

BACKGROUND: Left ventricular (LV) ischemia has been variably associated with functional mitral regurgitation (FMR). Determinants of FMR in patients with ischemia are poorly understood. OBJECTIVES: This study sought to test whether contractile mechanics in ischemic myocardium underlying the mitral valve have an impact on likelihood of FMR. METHODS: Vasodilator stress perfusion cardiac magnetic resonance was performed in patients with coronary artery disease (CAD) at multiple centers. FMR severity was confirmed quantitatively via core lab analysis. To test relationship of contractile mechanics with ischemic FMR, regional wall motion and strain were assessed in patients with inducible ischemia and minimal (≤5% LV myocardium, nontransmural) infarction. RESULTS: A total of 2,647 patients with CAD were studied; 34% had FMR (7% moderate or greater). FMR severity increased with presence (P < 0.001) and extent (P = 0.01) of subpapillary ischemia: patients with moderate or greater FMR had more subpapillary ischemia (odds ratio [OR]: 1.13 per 10% LV; 95% CI: 1.05-1.21; P = 0.001) independent of ischemia in remote regions (P = NS); moderate or greater FMR prevalence increased stepwise with extent of ischemia and infarction in subpapillary myocardium (P < 0.001); stronger associations between FMR and infarction paralleled greater wall motion scores in infarct-affected territories. Among patients with inducible ischemia and minimal infarction (n = 532), wall motion and radial strain analysis showed impaired subpapillary contractile mechanics to associate with moderate or greater FMR (P < 0.05) independent of remote regions (P = NS). Conversely, subpapillary ischemia without contractile dysfunction did not augment FMR likelihood. Mitral and interpapillary dimensions increased with subpapillary radial strain impairment; each remodeling parameter associated with impaired subpapillary strain (P < 0.05) independent of remote strain (P = NS). Subpapillary radial strain (OR: 1.13 per 5% [95% CI: 1.02-1.25]; P = 0.02) and mitral tenting area (OR: 1.05 per 10 mm2 [95% CI: 1.00-1.10]; P = 0.04) were associated with moderate or greater FMR controlling for global remodeling represented by LV end-systolic volume (P = NS): when substituting sphericity for LV volume, moderate or greater FMR remained independently associated with subpapillary radial strain impairment (OR: 1.22 per 5% [95% CI: 1.02-1.47]; P = 0.03). CONCLUSIONS: Among patients with CAD and ischemia, FMR severity and adverse mitral apparatus remodeling increase in proportion to contractile dysfunction underlying the mitral valve.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Infarto , Isquemia , Espectroscopía de Resonancia Magnética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Miocardio , Perfusión , Valor Predictivo de las Pruebas
20.
J Cardiovasc Magn Reson ; 24(1): 38, 2022 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-35725565

RESUMEN

The 25th Society for Cardiovascular Magnetic Resonance (SCMR) Annual Scientific Sessions saw 1524 registered participants from more than 50 countries attending the meeting virtually. Supporting the theme "CMR: Improving Cardiovascular Care Around the World", the meeting included 179 invited talks, 52 sessions including 3 plenary sessions, 2 keynote talks, and a total of 93 cases and 416 posters. The sessions were designed so as to showcase the multifaceted role of cardiovascular magnetic resonance (CMR) in identifying and prognosticating various myocardial pathologies. Additionally, various social networking sessions as well as fun activities were organized. The major areas of focus for the future are likely to be rapid efficient and high value CMR exams, automated and quantitative acquisition and post-processing using artificial intelligence and machine learning, multi-contrast imaging and advanced vascular imaging including 4D flow.


Asunto(s)
Inteligencia Artificial , Sistema Cardiovascular , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...